Loading...
Drive Model Terminal
Recomm. Gauge
AWG, kcmil
Wire Range
AWG, kcmil
Screw
Size
Tightening Torque
N·m (lb.in.)
4A0139
<1>
R/L1, S/L2, T/L3 3/0 1/0 to 4/0
M10
18 to 23
(159 to 204)
U/T1, V/T2, W/T3 2/0 1/0 to 4/0
–, +1 1/0 to 4/0
+3 3 to 4/0
4 4
4A0165
<1>
R/L1, S/L2, T/L3 4/0 3/0 to 4/0
M10
18 to 23
(159 to 204)
U/T1, V/T2, W/T3 4/0 3/0 to 4/0
–,+1 1 to 4/0
+3 1/0 to 4/0
4 4 to 2
4A0208
<1>
R/L1, S/L2, T/L3 300 2 to 300
M10
18 to 23
(159 to 204)
U/T1, V/T2, W/T3 300 2 to 300
–,+1 1 to 250
+3 3 to 3/0
4 4 to 300
4A0250
<1>
R/L1, S/L2, T/L3 400 1 to 600
M10
18 to 23
(159 to 204)
U/T1, V/T2, W/T3 400 1/0 to 600
–,+1 3/0 to 600
+3 1 to 325
2 2 to 350
4A0296
<1>
R/L1, S/L2, T/L3 500 2/0 to 600
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 500 2/0 to 600
–,+1 3/0 to 600
+3 1 to 325 M10
18 to 23
(159 to 204)
2 2 to 350 M12
32 to 40
(283 to 354)
4A0362
<1>
R/L1, S/L2, T/L3 4/0 × 2P 3/0 to 600
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 4/0 × 2P 3/0 to 600
–,+1 4/0 to 600
+3 3/0 to 600 M10
18 to 23
(159 to 204)
1 1 to 350 M12
32 to 40
(283 to 354)
4A0414
<1> <2>
R/L1, S/L2, T/L3 300 × 2P 4/0 to 300
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 300 × 2P 4/0 to 300
–,+1 3/0 to 300
+3 3/0 to 300
1 1 to 3/0
4A0515
<1> <2>
R/L1, S/L2, T/L3 3/0 × 4P 3/0 to 300
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 4/0 × 4P 3/0 to 300
–,+1 1/0 to 300
+3 1/0 to 300
1/0 1/0 to 300
4A0675
<1> <2>
R/L1, S/L2, T/L3 300 × 4P 4/0 to 300
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 300 × 4P 4/0 to 300
–,+1 1/0 to 300
+3 1/0 to 300
2/0 2/0 to 300
<1> Drive models 4A0058 to 4A0675 require the use of UL-Listed closed-loop crimp terminals for UL/cUL compliance. Use only the tools recommended
by the terminal manufacturer for crimping.
<2> When installing an EMC filter, additional measures must be taken to comply with IEC61800-5-1. Refer to EMC Filter Installation on page 338
for details.
3.6 Main Circuit Wiring