10 Appendix
10-38
Pn502
20 Rotation Detection Level Immediately
Pn503
10
Speed Coincidence Signal Output
Width
Immediately
Pn506
0
Brake Reference
-
Servo OFF Delay
Time
Immediately
Pn507
100 Brake Reference Output Speed Level Immediately
Pn508
50
Waiting Time for Brake Signal When
Motor Running
Immediately
Pn509
20 Instantaneous Power Cut Hold Time Immediately
Pn50A
2100 Input Signal Selection 1 After restart
Pn50B
6543 Input Signal Selection 2 After restart
Pn50C
8888 Input Signal Selection 3 After restart
Pn50D
8888 Input Signal Selection 4 After restart
Pn50E
3211 Output Signal Selection 1 After restart
Pn50F
0000 Output Signal Selection 2 After restart
Pn510
0000 Output Signal Selection 3 After restart
Pn511
8888 Reserved
−
Pn512
0000 Output Signal Inverse Setting After restart
Pn513
0000 Reserved –
Pn515
8888 Input Signal Selection 6 After restart
Pn517
0000 Reserved –
Pn51B
1000 Reserved
−
Pn51E
100
Excessive Position Error Warning
Level
Immediately
Pn520
5242880
Excessive Position Error Alarm
Level
Immediately
Pn522
7 Positioning Completed Width Immediately
Pn524
1073741824 NEAR Signal Width Immediately
Pn526
5242880
Excessive Position Error Alarm
Level at Servo ON
Immediately
Pn528
100
Excessive Position Error Warning
Level at Servo ON
Immediately
Pn529
10000 Speed Limit Level at Servo ON Immediately
Pn52A
20 Reserved
−
Pn52B
20 Overload Warning Level Immediately
Pn52C
100
Derating of Base Current at Detecting
Overload of Motor
After restart
Pn52D
50 Reserved –
Pn52F
0FFF Monitor Display at Power ON Immediately
Pn530
0000
Program JOG Operation Related
Switch
Immediately
Pn531
32768 Program JOG Movement Distance Immediately
Pn533
500 Program JOG Movement Speed Immediately
Pn534
100
Program JOG Acceleration/Decelera-
tion Time
Immediately
Pn535
100 Program JOG Waiting Time Immediately
Pn536
1
Number of Times of Program JOG
Movement
Immediately
(cont’d)
Parameter
Factory
Setting
Name
When
Enabled