7.4 Fault
176 YASKAWA SIEPYEULA5001C LA500 Technical Manual
Code Name Causes Possible Solutions
EF3 External Fault (Terminal S3)
MFDI terminal S3 caused an external fault through
an external device.
1. Find the device that caused the external fault and remove the
cause.
2. Clear the external fault input in the MFDI.
The wiring is incorrect. Correctly connect the signal line to MFDI terminal S3.
External Fault [H1-03 = 20 to 2B] is set to MFDI
terminal S3, but the terminal is not in use.
Correctly set the MFDI.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
EF4 External Fault (Terminal S4)
MFDI terminal S4 caused an external fault through
an external device.
1. Find the device that caused the external fault and remove the
cause.
2. Clear the external fault input in the MFDI.
The wiring is incorrect. Correctly connect the signal line to MFDI terminal S4.
External Fault [H1-04 = 20 to 2B] is set to MFDI
terminal S4, but the terminal is not in use.
Correctly set the MFDI.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
EF5 External Fault (Terminal S5)
MFDI terminal S5 caused an external fault through
an external device.
1. Find the device that caused the external fault and remove the
cause.
2. Clear the external fault input in the MFDI.
The wiring is incorrect. Correctly connect the signal line to MFDI terminal S5.
External Fault [H1-05 = 20 to 2B] is set to MFDI
terminal S5, but the terminal is not in use.
Correctly set the MFDI.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
EF6 External Fault (Terminal S6)
MFDI terminal S6 caused an external fault through
an external device.
1. Find the device that caused the external fault and remove the
cause.
2. Clear the external fault input in the MFDI.
The wiring is incorrect. Correctly connect the signal line to MFDI terminal S6.
External Fault [H1-06 = 20 to 2B] is set to MFDI
terminal S6, but the terminal is not in use.
Correctly set the MFDI.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
EF7 External Fault (Terminal S7)
MFDI terminal S7 caused an external fault through
an external device.
1. Find the device that caused the external fault and remove the
cause.
2. Clear the external fault input in the MFDI.
The wiring is incorrect. Correctly connect the signal line to MFDI terminal S7.
External Fault [H1-07 = 20 to 2B] is set to MFDI
terminal S7, but the terminal is not in use.
Correctly set the MFDI.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
Err EEPROM Write Error
There was a problem with the EEPROM hardware. Re-energize the drive.
If the fault stays, replace the control board or the drive.
Contact Yaskawa or your nearest sales representative to
replace the board.
Electrical interference corrupted the data while it
was writing to the EEPROM of the drive.
Push ENTER Key.
Set the parameters again.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
FRL Speed Reference Missing
No speed reference is selected at start. Select speed reference before start.
Code Name Causes Possible Solutions
GF Ground Fault
Overheating caused damage to the motor or the
motor insulation is not satisfactory.
Measure the motor insulation resistance, and replace the motor if
there is electrical conduction or unserviceable insulation.
The motor main circuit cable is contacting ground
to make a short circuit.
Examine the motor main circuit cable for damage, and repair
short circuits.
Measure the resistance between the motor main circuit cable
and the ground terminal. If there is electrical conduction,
replace the cable.