Parameter Details
12
12.3 C: Tuning
YASKAWA SIEPYEULA5001C LA500 Technical Manual 289
Figure 12.4 Accel/Decel Time Switching Speed
■ C1-01: Acceleration Ramp 1
No.
(Hex.)
Name Description
Default
(Range)
C1-01
(0200)
RUN
Acceleration Ramp 1
Sets the ramp to accelerate from zero to maximum output speed.
1.50 s
(0.00 - 600.00 s)
■ C1-02: Deceleration Ramp 1
No.
(Hex.)
Name Description
Default
(Range)
C1-02
(0201)
RUN
Deceleration Ramp 1
Sets the ramp to decelerate from maximum output speed to zero.
1.50 s
(0.00 - 600.00 s)
■ C1-03: Acceleration Ramp 2
No.
(Hex.)
Name Description
Default
(Range)
C1-03
(0202)
RUN
Acceleration Ramp 2
Sets the ramp to accelerate from zero to maximum output speed.
1.50 s
(0.00 - 600.00 s)
■ C1-04: Deceleration Ramp 2
No.
(Hex.)
Name Description
Default
(Range)
C1-04
(0203)
RUN
Deceleration Ramp 2
Sets the ramp to decelerate from maximum output speed to zero.
1.50 s
(0.00 - 600.00 s)
■ C1-05: Acceleration Ramp 3
No.
(Hex.)
Name Description
Default
(Range)
C1-05
(0204)
RUN
Acceleration Ramp 3
Sets the ramp to accelerate from zero to maximum output speed.
1.50 s
(0.00 - 600.00 s)
■ C1-06: Deceleration Ramp 3
No.
(Hex.)
Name Description
Default
(Range)
C1-06
(0205)
RUN
Deceleration Ramp 3
Sets the ramp to decelerate from maximum output speed to zero.
1.50 s
(0.00 - 600.00 s)