12.4 d: References
298 YASKAWA SIEPYEULA5001C LA500 Technical Manual
d1-22: Intermed Speed 3
No.
(Hex.)
Name Description
Default
(Range)
d1-22
(02C4)
RUN
Intermed Speed 3
Sets the speed reference when intermediate speed 3 is selected by digital inputs.
0.00 Hz
(0.00 - 120.00 Hz)
d1-23: Releveling Speed
No.
(Hex.)
Name Description
Default
(Range)
d1-23
(02C5)
RUN
Releveling Speed
Sets the speed reference when releveling speed is selected by digital inputs.
0.00 Hz
(0.00 - 120.00 Hz)
d1-24: Inspect Oper Spd
No.
(Hex.)
Name Description
Default
(Range)
d1-24
(02C6)
RUN
Inspect Oper Spd
Sets the speed reference when inspection speed is selected by digital inputs.
30.00 Hz
(0.00 - 120.00 Hz)
d1-25: Rescue Oper Spd
No.
(Hex.)
Name Description
Default
(Range)
d1-25
(02C7)
RUN
Rescue Oper Spd
Sets the speed reference when rescue speed is selected by digital inputs.
5.00 Hz
(0.00 - 15.00 Hz)
d1-26: Leveling Speed
No.
(Hex.)
Name Description
Default
(Range)
d1-26
(02C8)
RUN
Leveling Speed
Sets the speed reference when leveling speed is selected by digital inputs.
4.00 Hz
(0.00 - 120.00 Hz)
d1-28: Nom/Lev Spd Det
No.
(Hex.)
Name Description
Default
(Range)
d1-28
(02CA)
Nom/Lev Spd Det
Sets the speed reference level to detect that leveling speed has been selected when multi speed
input commands are used.
0.00 Hz
(0.00 - 120.00 Hz)
d1-29: Inspect Spd Det
No.
(Hex.)
Name Description
Default
(Range)
d1-29
(02CB)
Inspect Spd Det
Sets the speed reference level to detect that inspection speed has been selected when multi speed
input commands are used.
0.00 Hz
(0.00 - 120.00 Hz)
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV