Parameter Details
12
12.9 o: Keypad-Related Settings
YASKAWA SIEPYEULA5001C LA500 Technical Manual 359
No. Item
Number
of
Charac
ters
Example Description
7 Drive capacity 2 62 Setting value (Hex.) of o2-04 [Drive Model (KVA) Selection]
8 Sampling time 5
(Maximum)
1000 Setting value (Dec.) of o5-02 [Log Sampling Interval]
Unit: ms
9 Row number 6 000001 Row number (Hex.) in the data log file
*1 If you do not set the time in the keypad, the text string of [000000000000] is generated to show the time.
Second Row: Log Data Information
This example shows the data text strings and data generated for the second row of log data.
Example of generated data:
01,0012,160107111230,0101,0201,0102,0201,0103,0206,0107,0005,0108,0209,0000,0000,0000,0000,0000,0
000,0000,0000,0000,0000,0000,0000,0000,0000,000002
No. Item
Number of
Characters
Description
1 Attribute 2 [01] shows that the record is a log data information record.
2 File number 4 Generates the [xxx] part (a 3-digit decimal number) of the [GLOG0xxx.csv] filename of the log data in hexadecimal
format.
3 Time stamp 12 Date file was generated
4 Monitor Number 1
*1
4 Monitor number selected by o5-03 [Log Monitor Data 1]
Ex.: 0101 (Dec.) for U1-01
5 Monitor Unit 1
*2
4 Unit code and number of decimal places used for the monitor selected with o5-03
Example when U1-01 = 30.00 Hz:
Number of decimal places = 2, Hz unit code = 01, monitor unit 1 = 0201 (Hex.)
6 Monitor number 2 4 Monitor number (Dec.) selected by o5-04 [Log Monitor Data 2]
7 Monitor Unit 2 4 Unit code and number of decimal places used for the monitor selected with o5-04
: : : :
22 Monitor number 10 4 Monitor number (Dec.) selected by o5-12 [Log Monitor Data10]
23 Monitor Unit 10 4 Unit code and number of decimal places used for the monitor selected with o5-12
24 to 27 Reserved 4 -
28 Row number 6 Row number (Hex.) in the data log file
*1 If there is no data log monitor selected, the text string of [0000] is generated.
*2 Refer to Table 12.15 for information about unit codes.
Table 12.15 Unit Codes
Unit Code (Hex.) Unit Unit Code (Hex.) Unit Unit Code (Hex.) Unit Unit Code (Hex.) Unit
00 08 PPR 10 H 18 0H
01 Hz 09 kW 11 V 19
02 RPM 0A Ω 12 us 1A
03 % 0B ms 13 min 1B
04 VAC 0C kHz 14 °C 1C
05 VDC 0D PSI 15 W 1D
06 A 0E MPM 16 kWH 1E
07 sec 0F FPM 17 MWH 1F
Third and Subsequent Rows: Log Data
This example shows the data text strings and data generated for the third row of log data.
Example of generated data:
02,0012,160107111239,1770,1770,00BE,0118,0028,0000,0000,0000,0000,0000,0000,0000,00000C
No. Item
Number of
Characters
Description
1 Attribute 2 [02] shows that the record is a monitor data record.
2 File number 4 Generates the [xxx] part (a 3-digit decimal number) of the [GLOG0xxx.csv] filename of the log data in hexadecimal
format.

Table of Contents

Other manuals for YASKAWA LA500