Startup Procedure and Test Run
4
4.7 Setup Procedure for Elevator Applications
YASKAWA SIEPYEULA5001C LA500 Technical Manual 99
Figure 4.18 Wiring Diagram when Using a UPS
Figure 4.19 Magnetic Contactor Sequence
Starting Rescue Operation :
1. Open contactor B.
2. Set the input terminal programmed for Rescue Operation [H1-xx = 55].
3. Close contactor A.
4. Set the Up/Down command.
Ending Rescue Operation :
1. After the car has stopped, open contactor A.
2. Clear the input terminal set for Rescue Operation [H1-xx = 55].
3. Close contactor B to return to operation with normal power supply.