Maintenance and inspection
9 - 53
9.4 Draining off condensation water
Fig. 9-9: Dew Condensation Water Exhaust
1. Set the U-arm horizontally.
2. Remove the sealing plugs from the condensed water outlet opening,
3. Drain condensation water.
4. Please apply Teroson Plast sealing compound (material no. 143813) to the plug
threads with 5 Nm and insert them in the condensation water outlets.
5. Tighten the plug again.
NOTICE
The condensed water outlet opening varies depending on the type of assembly (see the
picture.
Dew Condensation Water Exhaust Condensed water outlet opening in
the ceiling mounting
Condensed water outlet opening in
the floor mounting
Condensed water outlet opening in
the wall mounting
PT1/8
PT1/8
PT1/8
1
3
2
4

Table of Contents