C-7
168542-1CD
168542-1CD
MLX200 Software and
Operations
Appendix C
C.1 MLX200 Control Module Error Code List
608 2624 Servo
Communication
Error
System Initialization Error. The
initialization at power on sequence
was failed.
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
609 2625 Servo
Communication
Error
Communication Device Initialization
Error. The ESC initialization was
failed.
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
610 2631 Servo
Communication
Error
Loading Servo Information Error. The
loading of SERVOPACK information
was failed.
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
611 2632 Servo
Communication
Error
EEPROM Parameter Data Error. The
checksum in EEPROM is broken.
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
700 32 Servo Drive
Fault
Parameter Checksum Error. The
data of the parameter in the
SERVOPACK is incorrect.
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
701 33 Servo Drive
Fault
Parameter Format Error. The data
format of the parameter in the
SERVOPACK is incorrect
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
702 34 Servo Drive
Fault
System Checksum Error. The data of
the parameter in the SERVOPACK is
incorrect.
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
703 48 Servo Drive
Fault
Main Circuit Detector Error. Detection
data for power circuit is incorrect.
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
704 64 Servo Drive
Fault
Parameter Setting Error. The
parameter setting is outside the
allowable setting range.
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
705 65 Servo Drive
Fault
Encoder Output Pulse Setting Error.
The encoder output pulse setting
(pulse unit) (Pn212) is outside the
allowable setting range or does not
satisfy the setting conditions.
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
706 66 Servo Drive
Fault
Parameter Combination Error.
Combination of some parameters
exceeds the setting range.
“See Chapter 9 of Sigma-V Series,
AC Servo Drives, USER'S MANUAL.
Model: SGDV-OCA01A EtherCAT
(CoE) Network Module. MANUAL
NO. SIEP C720829 04A”
MLx
Error #
OEM
Error #
Message Description Remedy