9-8
157569-1CD
HW0485652
MPL100
9 Maintenance and Inspection
9.2 Notes on Maintenance Procedures
Fig. 9-2(c): Battery Location (Top View)
Fig. 9-3: Battery Connection
1. Turn OFF the DX100 main power supply.
2. Remove the plate fixing screws and the plate on the connector base,
then
pull the battery pack out to replace it with the new one.
3. Remove the battery pack from the battery holder.
4. Connect the new battery pack to the unoccupied connector on the
bo
ard.
5. Remove the old battery pack from the board.
Battery pack
Board
New battery pack
(HW0470360-A)
Battery pack before replacement
See the step 5.
See the step 4.
Connector
Board
NOTE
Remove the old battery pack after connecting the new one
so that the encoder absolute data does not disappear.