3-4
180788-1CD
HW1484370
3 Installation
3.2 Mounting Procedures for Manipulator Base
MPX2600
3.2.2 How to Install the Pressure Switch
For mounting the pressure switch unit, two ways are available: the vertical
installation (factory setting position) and the horizontal installation.
Fix the unit securely by using the hexagon socket head cap screw M5
(4 screws).
For the installation method, refer to Fig. 3-3 “Installing the Pressure Switch
Unit”.
Fig. 3-3: Installing the Pressure Switch Unit
Bracket
(Installation position of
the bracket is changed.)
Screws for installation (delivered with the manipulator)
Hexagon socket head cap screw M5
(length: 16 mm, 4 scews)
Washer M5 (4 washers)
Tightening torque: 6.00 Nm (0.6 kgfm)
Horizontal Installation
Enlarged View of C (Fixing part)
(113)
Vertical Installation (factory setting position)
(R)
7
C part (4 places)
C part (4 places)
408
(235)
220
201
113
242
(260)
(235)
220
434
113
(448)
201
399