4 Wiring
4.4 Installation Site
4-16
180788-1CD
HW1484370
MPX2600
4.4 Installation Site
This section describes the conditions of the installation site for the robot
system. Only devices that are approved as explosion-proof can be
installed in hazardous locations. Refer to the local regulations and safety
codes for the definition of a hazardous location. Install the controller and
control panels in a location free from water drops, dust, and dirt.
System Components Hazardous
Location
(Inside Painting
Booth)
Non-hazardous
location
(Outside Painting
Booth)
Ambient
Temperature
Maximum
Ambient
Humidity
Manipulator (explosion-proof)
0 to 40 °C 80%RH
DX200
(not explosion-proof)
×
0 to 45 °C 90%RH
Pressure Switch unit
(explosion-proof)
× 0 to 40°C 85%RH
Programming pendant
(not explosion-proof)
×
0 to 40 °C 85%RH
Programming pendant (explosion-
proof) (Optional)
••
0 to 40 °C 85%RH
DANGER
In case installing the MOTOMAN-MPX2600 in the hazardous area,
classify the manipulator environment by following the local
explosion-proof standard and then, on the basis of the explosion-
proof structure notation on the MOTOMAN-MPX2600, confirm that
the manipulator is possible to install in that area.
WARNING
Devices that are not explosion-proof must not be installed in hazardous
locations. Failure to observe this warning may result in a fire.