E1101000117GB01 39
7.2.1 Electric cable
Contacts marked with identical numbers on the connections at both cable ends are connected
to each other.
7.2.2 pneumatic tubes
Fittings for ø 6 mm and ø 4 mm (outer diameter) for pneumatic hoses are provided at both
hose ends.
Table 3 Internal wiring
Rated Voltage
Current
Capacity
Leads
Nominal cross
section
outside diameter Notice
AC/DC30 V 1 A 15
0.211 mm
2
ø8.3±0.3 mm shielded
Table 4 Connector types
Maker Stdandard
15 pin Applicable plug: JAE DA-15PF-N (Solder Type)
Clamping hood JAE DA-C8-J10-F2-1 (connection setscrew: #4-40 NC)
9 pin Applicable plug: JAE DE9PF-N (Solder Type)
Clamping hood JAE DE-C8-J9-F2-1R (connection setscrew: #4-40 NC)
Table 5 Internal pneumatic tubes
Max. permissible pneumatic pressure pneumatic tubes Outside diameter × Inside diameter
0.59 Mpa 2 ø6 mm x ø4 mm