4.2 Power Supply
4-5
4.2.4 Primary Power Supply Switch Installation
Install the primary power supply switch as shown.
Installation of the Primary Power Supply Switch
The maximum load value (payload, operation speed, and frequency, etc.) is displayed.
However, the power capacity is different depending on work conditions.
Inquire at the nearest branch office listed on the back cover for information when selecting the
transformer.
NX100 Power Capacity, Cable Sizes, and Switch Capacities
Manipulator
Power
capacity
(kVA)
Cable size (size of terminal)
(In case of Cabtyre cable (four wicks))mm
2
Switch
capacity for
NX100
(A)
HP3 1 3.5 (M5) 5
HP6, EA1400N 1.5 3.5 (M5) 10
HP20, EA1900N 2.8 3.5 (M5) 15
UP20MN, UP50N 5 5.5 (M5) 20
ES200N, HP165,
ES165N
7.5 5.5(M5) 30
ES165RN,
ES200RN
8.5 5.5 (M5) 30
Breake