4.2 Addition of Base and Station Axis
4-4
*2
The setup display is shown.
*3
The display moves to the control group display shown in the followings pages.
The following items must be set for base and station axes.
-TYPE
Select one in the type list.
In case of base axis (B1,B2,B3)
Select one of RECT-X, -Y, -Z, -XY, -XZ, -YZ or -XYZ.
In case of station axis (S1,S2,S3,S4,S5,S6)
Select one of TURN-1, -2.
In case of other type, select one of UNIV-1, -2, -3, -4, -5, -6
-CONNECTION
In the connection display, specify the SERVOPACK which is connected with each axis
group and the contactor which is used for the SERVOPACK.
-AXIS TYPE
Select one in the axis type list.
In case of TURN-* type
No need to select (The axis type is set as TURN type.)
In case of RECT-* type
Select BALL-SCREW type or RACK & PINION type.
In case of UNIV-* type
Select BALL-SCREW type, RACK & PINION type or TURN type.
-MECHANICAL SPECIFICATION
If axis type is ball-screw type, set the following items.
MOTION RANGE (+) [mm]
MOTION RANGE (-) [mm]
REDUCTION RATIO (numerator)
REDUCTION RATIO (denominator)
BALL-SCREW PITCH [mm/r]
If axis type is rack & pinion type, set the following items.
SETUP
LANGUAGE
CONTROL GROUP
APPLICATION
IO MODULE
OPTION BOARD
CMOS MEMORY
DATE CLOCK
!Maintenance Mode
Item marked by
"
can not be set.

Table of Contents