EasyManua.ls Logo

YASKAWA Motoman UP6 - 6 Allowable Load for Wrist Axis and Wrist Flange; 6.1 Allowable Wrist Load

YASKAWA Motoman UP6
561 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.1 Allowable Wrist Load
6-1
6
Allowable Load for Wrist Axis and Wrist
Flange
6.1
Allowable Wrist Load
The allowable wrist load is 6kg. If force is applied to the wrist instead of the load, force on R-,
B-, and T-Axes should be within the value shown in " Table. 4 Moment and Total Inertia ".
Contact your Yaskawa representative for further information or assistance.
*1
( ): Gravitational unit
When the volume load is small, refer to the moment arm rating shown in " Fig. 14 Moment
Arm Rating ".
The allowable total inertia is calculated when the moment is at the maximum. Contact your
Yaskawa representative when only inertia moment, or load moment is small and inertia
moment is large. Also, when the load mass is combined with an outside force, contact your
Yaskawa representative.
Fig. 14 Moment Arm Rating
Table. 4 Moment and Total Inertia
Axis
Moment N•m (kgf•m)
*1
GD
2
/4 Total Inertia kg•m
2
R-Axis
B-Axis
T-Axis
11.8 (1.2)
9.8 (1.0)
5.9 (0.6)
0.24
0.17
0.06
B-Axis Rotaion
Center Line
Load Gravity
Position