System Setup
9 - 109
4. Press [FWD] again.
– Press [FWD] again, and measurement of T-axis starts.
1) Measurement of the T-axis: T-axis home position +30 degrees -30 degrees
When the measurement is completed, the measured data appears on the screen
NOTICE
During the measurement, the [FWD] button must be kept pressed. If the button is
released during the measurement or if it is released before “” changes into “”, the
measurement is aborted and the following message appears
“Stopped measurement” The measurement starts again from the home position2.
5. Select “REGISTER” (When measuring only the tool load and the center of gravity).
The measured data is registered in the tool file, and the tool coordinate window
appears.
Select “CANCEL” to open the tool list window without registering the measured data in
the tool file.