System Setup
9 - 189
9.18 File Initialization
9.18.1 Initializing JOB files
1. Turn the power supply ON while pressing [Main Menu] simultaneously.
2. The security mode is changed to the management mode.
3. Select {FILE} under the main menu.
4. Select {INITIALIZE}.
– The INITIALIZE window appears.
5. Select {JOB}
– A confirmation dialog box appears.
6. Select {YES}.
– The JOB data is initialized.
NOTICE
When JOB is initialized, the following files are reset at the same time. Be careful when
initializing JOB.
User coordinates
Memory play file (only for extended CMOS)
Spot monitor data (only for extended CMOS)
Variable data
System definition parameter (S4D)
Robot calibration data
Conveyor calibration data
9.18.2 Initialize data files
1. Turn the power supply ON while pressing [Main Menu] simultaneously.
2. The SECURITY mode is changed to the MANAGEMENT mode.