System Setup
9 - 295
<The safety logic circuit: example 2>
1. In the following example, one second after the emergency button of the programming
pendant (PPESP) is pressed and the general purpose safety input signal1 is OFF, the
general purpose safety output signal1(#1 GSOUT1) is turned ON.
2. Displays the time chart.
3. Verifying the safety logic circuit.
Confirm that the mark “” becomes ““ when pressing the programming pendant and
switching the general purpose safety signal ON. The mark “” of the general purpose
safety output signal 1 becomes ““ after one second passed.
<The safety logic circuit: example 3>
• Signal 1 : Programming pendant emergency button (PPESP)
• Signal 2 : NOT general purpose safety input signal 1 (#1 GSIN1
• Logic : AND
• Output signal : General purpose safety output signal 0 (#1 GSOUT0)
• Timer : ON delay timer1 (TM1 ON DELAY) 1 second
Timer (Start)
Timer (Reaching the specified value)
PPESP and NOT #1 GSIN1 are ON and ON DELAY TIM1 reached to the specified
value so that #1 GSOUT1 will be ON.
1
2
3