Modification of System Configuration
13 - 382
3. An overrun signal is allocated to a control group. Therefore, when an overrun alarm
occurs, the sub code is indicated by the control group.
However, select “NOT CONNECT” if an overrun switch is not installed to the control
group or the allocation of the external axis overrun signal is not needed.
Regarding the connection of the external axis overrun signal, refer to chapter 15.12
"External axes overrun"”.
4. Select a desired item.
5. Press [ENTER] in the CONNECT window.
– The setting in the CONNECT window is completed and the window moves to the AXES
CONFIG window.
Contactor unit (TU #1), Brake connector (BRK7)
Converter (CV #2)
2. Axis SERVO board (SV #1), Connector (8CN)
Contactor unit (TU #1), Brake connector (BRK8)
Converter (CV #3)
Overrun (OT2)