8.3 Alarm Message List
8-24
1214 PBESP RELAY
STICKING
0000_
00
∗∗
The emergency stop button PBESP
of the NX100 front door is melted
and stuck.
0000_0001: 1 signal (PLD1) error
0000_0010: 2 signal (PLD2) error
• Confirm that the cable is not short-circuited.
• Replace if necessary.
1215 PPESP RELAY
STICKING
0000_
00
∗∗
The emergency stop button of pro-
gramming pendant PPESP is
melted and stuck.
0000_0001: 1 signal (PLD1) error
0000_0010: 2 signal (PLD2) error
• Confirm that the cable is not short-circuited.
• Replace if necessary.
1216 EXESP RELAY
STICKING
0000_
00
∗∗
The external emergency stop but-
ton EXESP is melted and stuck.
0000_0001: 1 signal (PLD1) error
0000_0010: 2 signal (PLD2) error
• Confirm that the cable is not short-circuited.
• Replace if necessary.
1217 S_ON RELAY
STICKING
0000_
00
∗∗
The servo-ON relay is melted and
stuck.
0000_0001: 1 signal (PLD1) error
0000_0010: 2 signal (PLD2) error
Replace the servo-ON relay.
1218 B_ON RELAY
STICKING
0000_
00
∗∗
The brake relay is melted and
stuck.
0000_0001: 1 signal (PLD1) error
0000_0010: 2 signal (PLD2) error
Replace the brake relay.
1219 ANOTHER PLD
EXT WDT
ERROR (NIF
BOARD)
0000_
00
∗∗
The watchdog timer checking the
safety circuit is incorrect.
• Turn the power OFF then back ON.
If the error occurs again, replace the NIF unit.
1220
LAN COMMUNI-
CATION PARAM-
ETER ERROR
1 Incorrect setting of the IP address
which is used in the Ethernet func-
tion.
Set the correct IP address.
2 Incorrect setting of the subnet mask
which is used in the Ethernet func-
tion.
Set the correct subnet mask.
3 Incorrect setting of the default gate-
way which is used in the Ethernet
function.
Set the correct default gateway.
4 Incorrect setting of the host address
which is used in the Ethernet func-
tion.
Set the correct host address.
30 Incorrect setting of the parameter
which is used for the SNTP of the
Ethernet function.
Set the network SNTP in maintenance mode.
31 Incorrect setting of the IP address
of the SNTP server which is used in
the Ethernet function of the SNTP.
Set the correct network SNTP server address
in maintenance mode.
32 Incorrect setting of the host name
of the SNTP server which is used in
the Ethernet function of the SNTP.
Set the correct network SNTP server host
name in maintenance mode.
33 Incorrect setting of the parameter of
the DFCP which is used in the
Ethernet function of the SNTP.
Set the network SNTP in maintenance mode.
70 Incorrect setting of the host name
which is used in the Ethernet func-
tion.
Set the correct network SNTP server host
name.
71 Incorrect setting of the IP address
of the DNS server which is used in
the Ethernet function of the DNS.
Set the correct DNS server IP address.
73 Incorrect setting of the parameter of
the DHCP which is used in the
Ethernet function of the DNS.
Set the network DNS in maintenance mode.
74