8.3 Alarm Message List
8-47
4141 SNTP ERROR
4 The IP address error occurred in
the SNTP process of the Ethernet
function.
• Correctly set the IP address of the SNTP
server.
• If the DHCP is used, verify the DHCP server
operation and the network status.
5 Time-out occurred in the SNTP pro-
cess of the Ethernet function.
Verify the SNTP server operation and the
network status.
6 The server time is not synchronized
in the SNTP process of the Ether-
net function.
Verify the SNTP server operation.
7 The SNTP process of the Ethernet
function is not compliant with the
version that the server sent.
Use the server compliant with the SNTP ver-
sion 3.
8 Illegal parameters were found in the
SNTP process of the Ethernet func-
tion.
• Verify the SNTP related settings.
If the error occurs again, contact your
Yaskawa representative.
9 The SNTP process of the Ethernet
function was not successfully com-
pleted.
10 The name resolution error occurred
in the SNTP process of the Ether-
net function.
• Set a correct IP address for the SNTP
server.
• When the DHCP is used, verify the DHCP
server operation and the network status.
11 The error on getting of server
address occurred in the SNTP pro-
cess of the Ethernet function.
• When the DHCP is used, verify the DHCP
server operation.
12 The server setting is incorrect in the
SNTP process of the Ethernet func-
tion.
• Set a correct IP address for the SNTP
server.
4200 SYSTEM
ERROR
(FILE DATA)
--- An error occurred during the access
to file data (during file edition or
external memory device operation).
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
4201
SYSTEM
ERROR (JOB)
An error occurred when accessing to job
data.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
-1 • An error occurred in parameter
specification.
-2 • Access time exceeded the limit.
-3 • The access to a job could not be
performed with the specified job
name.
-4 • The character not allowed was
used as a job name.
-5 • A job was newly created with the
same name of the job already
specified in the memory.
-6 • The allowable job registration
area (memory) was exceeded.
Delete unused jobs and/or expand CMOS.
-7 • A job that did not exist in the
memory was specified.
• Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
-8 • An attempt was made to change
the contents for the job prohibited
from being edited.
Release the prohibition and change it.
-9 • An error occurred in handle value. • Reset the alarm, and then try again.
• Turn the power OFF then back ON.
If the error occurs again, contact your
Yaskawa representative.
Alarm Message List