EasyManua.ls Logo

YASKAWA SGD7S-200A - Page 234

YASKAWA SGD7S-200A
267 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.2 List of Parameters
9.2.2 List of Parameters
9-34
Pn533 2
Program Jog Operation
Movement Speed
1 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1
min
-1
500 Rotary
Immedi-
ately
Setup
*1
Pn534 2
Program Jog Operation
Acceleration/Decelera-
tion Time
2 to 10,000 1 ms 100 All
Immedi-
ately
Setup
*1
Pn535 2
Program Jog Operation
Waiting Time
0 to 10,000 1 ms 100 All
Immedi-
ately
Setup
*1
Pn536 2
Program Jog Operation
Number of Movements
0 to 1,000 Times 1 All
Immedi-
ately
Setup
*1
Pn550 2
Analog Monitor 1 Offset
Voltage
-10,000 to
10,000
0.1 V 0 All
Immedi-
ately
Setup
*1
Pn551 2
Analog Monitor 2 Offset
Voltage
-10,000 to
10,000
0.1 V 0 All
Immedi-
ately
Setup
*1
Pn552 2
Analog Monitor 1
Magnification
-10,000 to
10,000
× 0.01 100 All
Immedi-
ately
Setup
*1
Pn553 2
Analog Monitor 2
Magnification
-10,000 to
10,000
× 0.01 100 All
Immedi-
ately
Setup
*1
Pn55A 2
Power Consumption
Monitor Unit Time
1 to 1,440 1 min 1 All
Immedi-
ately
Setup
Pn560 2
Residual Vibration
Detection Width
1 to 3,000 0.1% 400 All
Immedi-
ately
Setup
Pn561 2
Overshoot Detection
Level
0 to 100 1% 100 All
Immedi-
ately
Setup
Pn580 2 Zero Clamping Level 0 to 10,000 1 mm/s 10 Linear
Immedi-
ately
Setup
*1
Pn581 2 Zero Speed Level 1 to 10,000 1 mm/s 20 Linear
Immedi-
ately
Setup
*1
Pn582 2
Speed Coincidence
Detection Signal Output
Width
0 to 100 1 mm/s 10 Linear
Immedi-
ately
Setup
*1
Pn583 2
Brake Reference Out-
put Speed Level
0 to 10,000 1 mm/s 10 Linear
Immedi-
ately
Setup
*1
Pn584 2
Speed Limit Level at
Servo ON
0 to 10,000 1 mm/s 10000 Linear
Immedi-
ately
Setup
*1
Pn585 2
Program Jog Operation
Movement Speed
1 to 10,000 1 mm/s 50 Linear
Immedi-
ately
Setup
*1
Pn586 2
Motor Running Cooling
Ratio
0 to 100
1%/
Max.
speed
0Linear
Immedi-
ately
Setup
Pn600 2
Regenerative Resistor
Capacity
*5
Depends on
model.
*6
10 W 0 All
Immedi-
ately
Setup
Pn601 2
Dynamic Brake Resis-
tor Allowable Energy
Consumption
0 to 65,535 10 J 0 All
After
restart
Setup
*7
Pn603 2
Regenerative Resis-
tance
0 to 65,535 10 mΩ 0All
Immedi-
ately
Setup
Pn604 2
Dynamic Brake Resis-
tance
0 to 65,535 10 mΩ 0All
After
restart
Setup
*7
Pn621 to
Pn628
*4
Safety Module-Related
Parameters
––All
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence

Table of Contents