No.
n.X
/MODE 0/1 (Mode Switch Input) Signal Allocation Reference
0 Mode 0 is used when CN1-40 input signal is ON (closed).
page 6-3
1 Mode 0 is used when CN1-41 input signal is ON (closed).
2 Mode 0 is used when CN1-42 input signal is ON (closed).
3 Mode 0 is used when CN1-43 input signal is ON (closed).
4 Mode 0 is used when CN1-44 input signal is ON (closed).
5 Mode 0 is used when CN1-45 input signal is ON (closed).
6 Mode 0 is used when CN1-46 input signal is ON (closed).
7 The signal always specifies mode 0.
8 The signal always specifies mode 1.
9 Mode 0 is used when CN1-40 input signal is OFF (open).
A Mode 0 is used when CN1-41 input signal is OFF (open).
B Mode 0 is used when CN1-42 input signal is OFF (open).
C Mode 0 is used when CN1-43 input signal is OFF (open).
D Mode 0 is used when CN1-44 input signal is OFF (open).
E Mode 0 is used when CN1-45 input signal is OFF (open).
F Mode 0 is used when CN1-46 input signal is OFF (open).
n.X
/START-STOP (Program Table Operation Start-Stop Input) Signal Alloca-
tion
Reference
0 Active when CN1-40 input signal is ON (closed).
page 6-3
1 Active when CN1-41 input signal is ON (closed).
2 Active when CN1-42 input signal is ON (closed).
3 Active when CN1-43 input signal is ON (closed).
4 Active when CN1-44 input signal is ON (closed).
5 Active when CN1-45 input signal is ON (closed).
6 Active when CN1-46 input signal is ON (closed).
7 The signal is always active.
8 The signal is always inactive.
9 Active when CN1-40 input signal is OFF (open).
A Active when CN1-41 input signal is OFF (open).
B Active when CN1-42 input signal is OFF (open).
C Active when CN1-43 input signal is OFF (open).
D Active when CN1-44 input signal is OFF (open).
E Active when CN1-45 input signal is OFF (open).
F Active when CN1-46 input signal is OFF (open).
n.X
/HOME (Homing Input) Signal Allocation Reference
0 to F
The settings are the same as for /START-STOP (Program Table
Operation Start-Stop Input) Signal Allocation.
page 6-3
n.X
/PGMRES (Program Table Operation Reset Input) Signal Allocation Reference
0 to F
The settings are the same as for /START-STOP (Program Table
Operation Start-Stop Input) Signal Allocation.
page 6-3