9.2 List of Parameters
9.2.2 List of Parameters
9-35
Pn630
2
Input Signal Selections
10
0000h to
FFFFh
6221h All
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
/MODE 0/1 (Mode Switch Input) Signal Allocation Reference
0 Mode 0 is used when CN1-40 input signal is ON (closed).
page 6-3
1 Mode 0 is used when CN1-41 input signal is ON (closed).
2 Mode 0 is used when CN1-42 input signal is ON (closed).
3 Mode 0 is used when CN1-43 input signal is ON (closed).
4 Mode 0 is used when CN1-44 input signal is ON (closed).
5 Mode 0 is used when CN1-45 input signal is ON (closed).
6 Mode 0 is used when CN1-46 input signal is ON (closed).
7 The signal always specifies mode 0.
8 The signal always specifies mode 1.
9 Mode 0 is used when CN1-40 input signal is OFF (open).
A Mode 0 is used when CN1-41 input signal is OFF (open).
B Mode 0 is used when CN1-42 input signal is OFF (open).
C Mode 0 is used when CN1-43 input signal is OFF (open).
D Mode 0 is used when CN1-44 input signal is OFF (open).
E Mode 0 is used when CN1-45 input signal is OFF (open).
F Mode 0 is used when CN1-46 input signal is OFF (open).
n.X
/START-STOP (Program Table Operation Start-Stop Input) Signal Alloca-
tion
Reference
0 Active when CN1-40 input signal is ON (closed).
page 6-3
1 Active when CN1-41 input signal is ON (closed).
2 Active when CN1-42 input signal is ON (closed).
3 Active when CN1-43 input signal is ON (closed).
4 Active when CN1-44 input signal is ON (closed).
5 Active when CN1-45 input signal is ON (closed).
6 Active when CN1-46 input signal is ON (closed).
7 The signal is always active.
8 The signal is always inactive.
9 Active when CN1-40 input signal is OFF (open).
A Active when CN1-41 input signal is OFF (open).
B Active when CN1-42 input signal is OFF (open).
C Active when CN1-43 input signal is OFF (open).
D Active when CN1-44 input signal is OFF (open).
E Active when CN1-45 input signal is OFF (open).
F Active when CN1-46 input signal is OFF (open).
n.X
/HOME (Homing Input) Signal Allocation Reference
0 to F
The settings are the same as for /START-STOP (Program Table
Operation Start-Stop Input) Signal Allocation.
page 6-3
n.X
/PGMRES (Program Table Operation Reset Input) Signal Allocation Reference
0 to F
The settings are the same as for /START-STOP (Program Table
Operation Start-Stop Input) Signal Allocation.
page 6-3