13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
13-13
Pn14F
2
Control-Related Selec-
tions
0000h
to
0021h
0021h All
After
restart
Tuning
Pn160
2
Anti-Resonance Con-
trol-Related Selections
0000h
to
0011h
0010h All
Immedi-
ately
Tuning
Pn161 2
Anti-Resonance Fre-
quency
10 to 20,000 0.1 Hz 1000 All
Immedi-
ately
Tuning
page
8-51
Pn162 2
Anti-Resonance Gain
Correction
1 to 1,000 1% 100 All
Immedi-
ately
Tuning
page
8-51
Pn163 2
Anti-Resonance Damp-
ing Gain
0 to 300 1% 0 All
Immedi-
ately
Tuning
page
8-51
Pn164 2
Anti-Resonance Filter
Time Constant 1 Cor-
rection
-1,000 to
1,000
0.01 ms 0 All
Immedi-
ately
Tuning
page
8-51
Pn165 2
Anti-Resonance Filter
Time Constant 2 Cor-
rection
-1,000 to
1,000
0.01 ms 0 All
Immedi-
ately
Tuning
page
8-51
Pn166 2
Anti-Resonance Damp-
ing Gain 2
0 to 1,000 1% 0 All
Immedi-
ately
Tuning
page
8-54
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Model Following Control Type Selection Reference
0 Use model following control type 1.
page 8-91
1 Use model following control type 2.
n.X
Tuning-less Type Selection Reference
0 Use tuning-less type 1.
page 8-131 Use tuning-less type 2.
2 Use tuning-less type 3.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X
Anti-Resonance Control Selection Reference
0 Do not use anti-resonance control.
page 8-51
1 Use anti-resonance control.
n.X
Anti-Resonance Control Adjustment Selection Reference
0
Do not adjust anti-resonance control automatically during execu-
tion of autotuning without a host reference, autotuning with a host
reference, and custom tuning.
page 8-32
1
Adjust anti-resonance control automatically during execution of
autotuning without a host reference, autotuning with a host refer-
ence, and custom tuning.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)