12.2 Alarm Displays
12.2.2 Troubleshooting Alarms
12-27
12
Maintenance
A.8A1:
External Encoder
Module Error
A failure occurred in
the external encoder.
Replace the external
encoder.
A failure occurred in
the Serial Converter
Unit.
Replace the Serial Con-
verter Unit.
A.8A2:
External Incre-
mental Encoder
Sensor Error
A failure occurred in
the external encoder.
Replace the external
encoder.
A.8A3:
External Abso-
lute Encoder
Position Error
A failure occurred in
the external absolute
encoder.
The external absolute
encoder may be faulty.
Refer to the encoder
manufacturer’s instruc-
tion manual for correc-
tions.
A.8A5:
External Encoder
Overspeed
An overspeed error
was detected in the
external encoder.
Check the maximum
speed of the external
encoder.
Keep the external
encoder below its maxi-
mum speed.
A.8A6:
External Encoder
Overheated
An overheating error
was detected in the
external encoder.
Replace the external
encoder.
A.b10:
Speed Reference
A/D Error
(Detected when
the servo is
turned ON.)
A malfunction
occurred in the speed
reference input sec-
tion.
Reset the alarm and
restart operation.
page 12-40
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.b11:
Speed Reference
A/D Data Error
A malfunction
occurred in the speed
reference input sec-
tion.
Reset the alarm and
restart operation.
page 12-40
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.b20:
Torque Refer-
ence A/D Error
(Detected when
the servo is
turned ON.)
A malfunction
occurred in the read-
ing section for the
torque reference
input.
Reset the alarm and
restart operation.
page 12-40
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.b33:
Current Detec-
tion Error 3
A failure occurred in
the current detection
circuit.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Continued on next page.
Continued from previous page.
Alarm Number:
Alarm Name
Possible Cause Confirmation Correction Reference

Table of Contents