12.2 Alarm Displays
12.2.2 Troubleshooting Alarms
12-29
12
Maintenance
A.C10:
Servomotor Out
of Control
(Detected when
the servo is
turned ON.)
The order of phases
U, V, and W in the
motor wiring is not
correct.
Check the Servomotor
wiring.
Make sure that the Servo-
motor is correctly wired.
There is an error in the
setting of Pn080 =
n.X (Motor
Phase Sequence
Selection).
Check the setting of
Pn080 = n.X.
Set Pn080 = n.X to
an appropriate value.
page 5-25
A failure occurred in
the encoder.
If the motor wiring is cor-
rect and an alarm still
occurs after turning the
power supply OFF and
ON again, the Servomotor
or linear encoder may be
faulty. Replace the Servo-
motor or linear encoder.
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.C20:
Phase Detection
Error
The linear encoder
signal level is too low.
Check the voltage of
the linear encoder sig-
nal.
Fine-tune the mounting of
the scale head. Or,
replace the linear
encoder.
The count-up direc-
tion of the linear
encoder does not
match the forward
direction of the Mov-
ing Coil in the motor.
Check the setting of
Pn080 = n.X
(Motor Phase Sequence
Selection). Check the
installation orientation
for the linear encoder
and Moving Coil.
Change the setting of
Pn080 = n.X.
Correctly reinstall the lin-
ear encoder or Moving
Coil.
page 5-25
The polarity sensor
signal is being
affected by noise.
Correct the FG wiring.
Implement countermea-
sures against noise for the
polarity sensor wiring.
A.C21:
Polarity Sensor
Error
The polarity sensor is
protruding from the
Magnetic Way of the
motor.
Check the polarity sen-
sor.
Correctly reinstall the
Moving Coil or Magnetic
Way of the motor.
The setting of Pn282
(Linear Encoder Scale
Pitch) is not correct.
Check the setting of
Pn282 (Linear Encoder
Scale Pitch).
Check the specifications
of the linear encoder and
set a correct value.
page 5-19
The polarity sensor is
not wired correctly.
Check the wiring of the
polarity sensor.
Correct the wiring of the
polarity sensor.
The polarity sensor
failed.
Replace the polarity sen-
sor.
A.C22:
Phase Informa-
tion Disagree-
ment
The SERVOPACK
phase information is
different from the lin-
ear encoder phase
information.
Perform polarity detec-
tion.
page 5-31
Continued on next page.
Continued from previous page.
Alarm Number:
Alarm Name
Possible Cause Confirmation Correction Reference

Table of Contents