EasyManua.ls Logo

YASKAWA SGD7S - Page 586

YASKAWA SGD7S
621 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14.1 List of Parameters
14.1.2 List of Parameters
14-22
Pn502 2 Rotation Detection Level 1 to 10,000
1 min
-1
20 Rotary
Immedi-
ately
Setup
page
6-10
Pn503 2
Speed Coincidence
Detection Signal Output
Width
0 to 100
1 min
-1
10 Rotary
Immedi-
ately
Setup
page
6-26
Pn506 2
Brake Reference-Servo
OFF Delay Time
0 to 50 10 ms 0 All
Immedi-
ately
Setup
page
5-37
Pn507 2
Brake Reference Out-
put Speed Level
0 to 10,000
1 min
-1
100 Rotary
Immedi-
ately
Setup
page
5-37
Pn508 2
Servo OFF-Brake Com-
mand Waiting Time
10 to 100 10 ms 50 All
Immedi-
ately
Setup
page
5-37
Pn509 2
Momentary Power Inter-
ruption Hold Time
20 to 50,000 1 ms 20 All
Immedi-
ately
Setup
page
6-12
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence

Table of Contents