14.1 List of Parameters
14.1.2 List of Parameters
14
Parameter Lists
14-25
Pn50C
2
Input Signal Selections
3
0000 to
FFFF
8888 All
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
/SPD-D (Motor Direction) Signal Allocation Reference
0 Active when CN1-40 input signal is ON (closed).
page 6-53
1 Active when CN1-41 input signal is ON (closed).
2 Active when CN1-42 input signal is ON (closed).
3 Active when CN1-43 input signal is ON (closed).
4 Active when CN1-44 input signal is ON (closed).
5 Active when CN1-45 input signal is ON (closed).
6 Active when CN1-46 input signal is ON (closed).
7 The signal is always active.
8 The signal is always inactive.
9 Active when CN1-40 input signal is OFF (open).
A Active when CN1-41 input signal is OFF (open).
B Active when CN1-42 input signal is OFF (open).
C Active when CN1-43 input signal is OFF (open).
D Active when CN1-44 input signal is OFF (open).
E Active when CN1-45 input signal is OFF (open).
F Active when CN1-46 input signal is OFF (open).
n.X
/SPD-A (Internal Set Speed Selection Input) Signal Allocation Reference
0 to F
The allocations are the same as the /SPD-D (Motor Direction) sig-
nal allocations.
page 6-53
n.X
/SPD-B (Internal Set Speed Selection Input) Signal Allocation Reference
0 to F
The allocations are the same as the /SPD-D (Motor Direction) sig-
nal allocations.
page 6-53
n.X
/C-SEL (Control Selection Input) Signal Allocation Reference
0 to F
The allocations are the same as the /SPD-D (Motor Direction) sig-
nal allocations.
page 6-57