Sigma II User’s Manual Chapter 5: Parameter Settings and Functions
5-101
5. When “PGCL5” is displayed, press the MODE/SET key. The display will
change as follows, and the absolute encoders multi-turn data will be cleared.
6. Press the DATA/ENTER key to return to the auxiliary function mode.
This completes the absolute encoders setup operation. Cycle the power to the servo
amplifier.
Setup Using the Built-in Panel Operator
1. Press the MODE/SET key to select the auxiliary function mode.
2. Press the Up Arrow or Down Arrow key to select the parameter Fn008.
3. Press the DATA/SHIFT key, holding it down for at least one second. The
following display will appear.
4. Press the Up Arrow key, holding it down until “PGCL5” is displayed. If an
erroneous key entry is made, “nO_OP” will flash for one second and the display
will return to the auxiliary function mode. In that case, go back to step 3 above
and perform the operation again.
5. When “PGCL5” is displayed, press the MODE/SET key. The display will
change as follows, and the absolute encoders multi-turn data will be cleared .
Flashes for
1 second.
Up Cursor Key
When an erroneous key entry is made
Flashes for one second.
Returns to auxiliary function mode.
Up Cursor Key