Sigma II User’s Manual Chapter 5: Parameter Settings and Functions
5-124
*1
This is the net value at the rated load.
When using a 400V class power supply, turn the power supply ON and OFF at the
primary side of the voltage conversion transformer.
Note: Transformer inductance will cause a surge voltage if the power is turned ON and OFF at the
secondary, damaging the servo amplifier.
Single-phase Power Supply Connection Example
Three-phase
200V
SGDH-05AE 1.4
SGDH-08AE 1.9
SGDH-10AE 2.3
SGDH-15AE 3.2
SGDH-20AE 4.3
SGDH-30AE 5.9
SGDH-50AE 7.5
SGDH-60AE 12.5
SGDH-75AE 15.5
SGDH-1AAE 22.7
SGDH-1EAE 30.9
Voltage
Servo Amplifier
Model
Voltage capacity per
Servo Amplifier
*1
kVA
U
V
W
1MC
1MC
1MC
Electromagnetic contactor for
power supply ON/OFF
Transformer for
voltage conversion
L1
L2
SGDH Servo amplifier