Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn498 2 Polarity
Detection
Allowable
Error Range
0 to 30 1 deg 10 Linear Immedi-
ately
Tuning
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn49F 2 Speed Ripple
Compensa-
tion Enable
Speed
0 to
10,000
1 mm/s 0 Linear Immedi-
ately
Tuning
Ä
Chap.
9.12
‘Speed
Ripple
Compen-
sation’
page 380
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn502 2 Rotation
Detection
Level
1 to
10,000
1 min
-1
20 Rotary Immedi-
ately
Setup
Ä
Chap.
7.2.6 ‘/
TGON
(Rotation
Detection)
Signal’
page 200
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn503 2 Speed Coin-
cidence
Detection
Signal Output
Width
0 to 100
1 min
-1
10 Rotary Immedi-
ately
Setup
Ä
Chap.
7.2.8 ‘/V-
CMP
(Speed
Coinci-
dence
Detection)
Signal’
page 202
Sigma-7 Series SERVOPACKs