n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X
P-OT (Forward Drive Prohibit) Signal Allocation Reference
0 Enable forward drive when CN1-13 input signal is
ON (closed).
Ä
Chap. 6.11.2
‘Overtravel Sig-
nals’ page 161
1 Enable forward drive when CN1-7 input signal is
ON (closed).
2 Enable forward drive when CN1-8 input signal is
ON (closed).
3 Enable forward drive when CN1-9 input signal is
ON (closed).
4 Enable forward drive when CN1-10 input signal is
ON (closed).
5 Enable forward drive when CN1-11 input signal is
ON (closed).
6 Enable forward drive when CN1-12 input signal is
ON (closed).
7 Set the signal to always prohibit forward drive.
8 Set the signal to always enable forward drive.
9 Enable forward drive when CN1-13 input signal is
OFF (open).
A Enable forward drive when CN1-7 input signal is
OFF (open).
B Enable forward drive when CN1-8 input signal is
OFF (open).
C Enable forward drive when CN1-9 input signal is
OFF (open).
D Enable forward drive when CN1-10 input signal is
OFF (open).
E Enable forward drive when CN1-11 input signal is
OFF (open).
F Enable forward drive when CN1-12 input signal is
OFF (open).
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn50B 2 Input Signal
Selections 2
0000h to
FFFFh
8882h All After
restart
Setup
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 709