Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn534 2 Program Jog-
ging Acceler-
ation/ Decel-
eration Time
2 to
10,000
1 ms 100 All Immedi-
ately
Setup
Ä
Chap.
8.7.2 ‘Pro-
gram Jog-
ging’
page 277
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn535 2 Program Jog-
ging Waiting
Time
0 to
10,000
1 ms 100 All Immedi-
ately
Setup
Ä
Chap.
8.7.2 ‘Pro-
gram Jog-
ging’
page 277
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn536 2 Program Jog-
ging Number
of Move-
ments
0 to 1,000 1 time 1 All Immedi-
ately
Setup
Ä
Chap.
8.7.2 ‘Pro-
gram Jog-
ging’
page 277
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn550 2 Analog Mon-
itor 1 Offset
Voltage
-10,000 to
10,000
0.1 V 0 All Immedi-
ately
Setup
Ä
Chap.
10.4
‘Moni-
toring
Machine
Operation
Status
and
Signal
Wave-
forms’
page 438
Sigma-7 Series SERVOPACKs