EasyManua.ls Logo

YASKAWA Sigma Mini SGMM Series - Page 110

YASKAWA Sigma Mini SGMM Series
283 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.7Designing a Protective Sequence
2-65
Preset value: Cn-22 (speed coincidence signal output width)
Set the following parameter to specify the output conditions for speed coincidence signal out-
put.
Cn-22
VCMPLV Speed Coincidence
Signal Output Width
Unit:
min
1
Setting
Range: 0
to 100
Factory
Setting:
10
For
Speed/Torque
Control
Set the output conditions for speed coincidence signal
/V-CMP.
The /V-CMP signal is output when the difference be-
tween the reference speed and actual motor speed is
not greater than the preset value.
Example: When preset value is 100 and reference
speed is 2000 min
1
.
/V-CMP is ON (circuit between CN1-8 and CN1-3 is closed) when the speed is between 1900
and 2100 min
1
.
2.7.5 Running Output Signal
This section describes how to wire and use contact output signal /TGON as a running output
signal. This signal indicates that a Servomotor is currently running.
CN1-8
CN1-3
/TGON
SG-COM
+24 V
Photocoupler output
Maximum operating voltage
per output: 30 VDC
Maximum output current
per output: 50 mA DC
Servopack
I/O power supply
0V
Output /TGON CN1-8
Running Output (Torque Limit
Output)
For Speed/Torque
Control and
Position Control
This output signal indicates that the motor is currently
running.
It is used as an external interlock.
2
Motor
speed
Reference
speed
/VCMP is output
within this range
Motor
speed
/TGON
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com