APPLICATIONS
2.2.2 Position Referencescont.
2-16
(2) The error counter clear (CLR) signal must be ON for at least 20 μs. Otherwise, it be-
comes invalid.
Allowable Voltage Level and Timing for Reference Pulse Input
Reference Pulse Form Electrical Specifications Remarks
Sign + pulse train input
(SIGN + PULS signal)
Maximum reference
frequency: 450 kpps
¨ reference © reference
The signs for each
reference pulse are as
follows:
¨: High level
©: Low level
90° different two-phase
pulse train
(phase A + phase B)
Maximum reference
frequency
x 1 multiplier:
450 kpps
x 2 multiplier:
400 kpps
x 4 multiplier:
200 kpps
Phase B is 90°
behind phase B
Phase A
Phase B
Phase B is 90°
forward from phase B
Parameter Cn-02 (bits 3,
4 and 5) is used to
switch the input pulse
multiplier mode.
CCW pulse + CW pulse
Maximum reference
frequency: 450 kpps
CCW pulse
CW pulse
¨ reference © reference
SIGN
PULS
Clearing the Error Counter
Use the following procedure to clear the contents of the error counter.
Input CLR CN1-18
Error Counter Clear Input For Position
Control
Input
/
CLR CN1-19
Error Counter Clear Input For Position
Control
Setting the CLR signal to high level will set the following conditions:
Sets the error counter inside the Servopack to 0.
Disables position loop control.
2
Positions
Servopack
Clear
Position loop
error counter