EasyManua.ls Logo

YASKAWA Sigma Mini SGMM Series - Page 68

YASKAWA Sigma Mini SGMM Series
283 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.2Setting Parameters According to Host Controller
2-23
The function of output signal OUT2 differs according to the setting of parameter Cn-2C.
Servopack
Setting Meaning
0 ALM (alarm output)
1 /TGON (rotation detection)
2 /BK (brake interlock output)
3 /V-CMP (speed coincidence output for speed/torque
control)
/COIN (positioning completed signal for positioning
control)
4 /CLT (torque limit detection output)
Output SG-COM CN1-3
Output Signal Ground
Common
For Speed/Torque
Control and
Position Control
This signal ground is used for the following output signals. Connect to 0 V on the external
power supply.
Contact Output Signals: ALM
/TGON
/BK
/V-CMP (for speed/torque control only)
/COIN (for position control only)
/CLT