APPLICATIONS
2.2.5 Electronic Gearcont.
2-26
6) Set the electronic gear ratio in the parameters below.
Reduce the electronic gear ratio
B
A
to their lowest terms so that both A and B are an
integer smaller than 65535, then set A and B in the following parameters.
B
A
Cn-24 RATB Electronic gear ratio (numerator)
Cn-25 RATA Electronic gear ratio (denominator)
Cn-24
RATB
Electronic Gear Ratio
Numerator
Unit:
None
Setting
Range: 1
to 65535
Factory
Setting: 4
For Position Control
Cn-25
RATA
Electronic Gear Ratio
Denominator
Unit:
None
Setting
Range: 1
to 65535
Factory
Setting: 1
For Position Control
These parameters are for position control only.
Set the electronic gear ratio according to machine
specifications.
Electronic gear ratio
B
A
=
Cn-24
Cn-25
B = [(Number of encoder pulses) x 4] x [Motor shaft rotating speed]
A = [Reference unit (load travel distance per revolution of load shaft)] x [Load shaft ro-
tating speed]
The parameter settings must meet the following condition:
0.01
B
A
100
The electronic gear settings are now complete.