398 YASKAWA ELECTRIC SIEP C710636 02B YASKAWA U1000 Technical Manual
7.4 Cooling Fan and Circulation Fan
7.4 Cooling Fan and Circulation Fan
NOTICE: Follow cooling fan replacement instructions. The cooling fan cannot operate properly when installed incorrectly and could
seriously damage the drive. To ensure maximum useful product life, replace all cooling fans when performing maintenance.
Contact a Yaskawa representative or the nearest Yaskawa sales office to order replacement cooling fans as required.
For drives with multiple cooling fans, replace all the fans when performing maintenance to ensure maximum product
performance life.
◆ Number of Fan
■ CIMR-U20028 to 20248, 40011 to 40930
■ Harmonic Filter Module
Three-Phase 200 V Class Three-Phase 400 V Class
Model
CIMR-U
Cooling Fan Circulation Fan Page
Model
CIMR-U
Cooling Fan Circulation Fan
Control Board
Cooling Fan
Page
20028 2 –
401
40011 2 – –
401
20042 2 – 40014 2 – –
20054 2 – 40021 2 – –
20068 2 – 40027 2 – –
20081 2 – 40034 2 – –
20104 2 – 40040 2 – –
20130 2 – 40052 2 – –
20154 3 –
403
40065 2 – –
20192 3 – 40077 2 – –
20248 1 2 407 40096 2 – –
––––40124 2 – –
––––40156 3 – –
403
––––40180 3 – –
––––40216 1 2 –
407
––––40240 1 2 –
––––40302 2 2 –
––––40361 2 2 –
––––40414 2 2 –
––––40477 4 4 2
412
––––40590 4 4 2
––––40720 4 4 2
416––––40900 4 4 2
––––40930 4 4 2
Model Cooling Fan Circulation Fan Control Board Cooling Fan Page
EUJ71180. 411422
EUJ71181. 411422
EUJ71182. 411422
EUJ71186. 411422
EUJ71187. 411422
EUJ71188. 411422
SIEP_C710636_02B_1_0.book 398 ページ 2015年11月25日 水曜日 午後4時56分