EasyManua.ls Logo

YASKAWA Varispeed-505WII - Adjuster Locations and Functions

YASKAWA Varispeed-505WII
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table
6
Control
Circuit
Board
Adjuster
Locations
and
Functions
Type
:
o
Adjuster
Adjuster
Adjuster
Function
Adjusting
Method
Specifications
Adjusters
Location
Name
1
~+
RATE
Accel
time
adjustment
at
fwdrun
.
Clockwise
rotation
increases
3
-
75
sec
(Decel
time
adjustment
at
rvs
run
.)
accel
time
.
2
(D
RATE
Decel
time
adjustment
at
fwd run
Clockwise
rotation
increases
decel
time
.
3
-
75
sec
(Accel
time
adjus
tment
at
rvs
run
.)
3
NGAIN
ASR
Gain
adjustment
.
Clockwise
rotation
increases
GAIN
4
Speed
feedback
adjustment
.
Clockwise
rotation
decreases
±
6
V/10046 specA
NMAX
s
"
geed
.
5
IGAIN
ACR
Gain adjustment
.
Clockwise
rotation
increases
gain
.
6
Main
circuit
current
feedback
Clockwise
rotation
decreases
+3
V/100%
current
IFB
adjustment
.
current
.
7
F
LIMIT
Speed and
current
limit
value
at
Clockwise
rotation
increases
150%
(Standard)
forward
run
.
limit
value
.
8
R
LIMIT
Speed
and
current
limit
value
at
Clockwise
rotation
increases
150%
(Standard)
reverse
run
.
li
mit
v
alue
.
9
CEMF
Counter
electromotive
force
Clockwise
rotation
increases
0
.
17 -
0
.84
times
Potenti-
compensation
.
gain
.
ometers
10
SM
Speedometer
adjustment
.
Clockwise
rotation
increases
1
mADC
max
.pointer
swin
:
.
Ammeter
adjustment
.
Clockwise
rotation
increases pointer
1
mADC
max
11
AM
swing
.
12
NOFS
ASR
offset
adjustment
.
evolt
.i
z- e
13
IOFS
ACR
offset
adjustment
.
t-volta
,",
.-e
14
KIPP
Phase
shift
lag
limit
adjust-
Clockwise
rotation
advances
shift
lag
155oek
Standard
ment
limit
Adjustment
of
phase
shifter
Clockwise
rotation
advances
90'-k
-
li_T1i°eZ
15
PSB
operation
point
.
:
,
hase
.
(Adjustable)
Setting
overload
detection
Clockwise
rotation
increases
110%
Standard
16
OL%
start
point
.
overload
detection
start
.
,
oin
t
.
17
OLT
Setting
overload
detection
Clockwise
rotation
increases
150%,
6
.0
sec
(Standard)
time
.
o
.eration
time
.
18
ZCD
Setting
zero
current
detec-
Clockwise
rotation
increases
0% -
10n
(Adjustable)
tion
level
.
detection
level
.
7%
(Standard)
19
IREF
Setting
field
current
.
Clockwise
rotation
increases
field
current
.
Resistor
20
14FBR
1FBR
-
Rough
adjustment
of
field
cur-
Selection
rent
detection
voltage
level
.
Open
the
resistor
according
Refer
to
motor
specifi-
(Open)
21
5FBR
-
Rough
adjustment
of
main
circuit
to
specifications
.
cations
.
9FBR
current
detection
voltage
level
.
Slide
22
1SW
Control
Method
selector
(Speed
N-1
Current
Switch
control)
control)
~
50
Hz-
"
0
Hz
Rough
adjustment
of
speed
Selection
o
the
voltage
level
24
A
-
D
detection
voltage
level
.
according
to
type
of
tack-gen
and
motor
rated
s
.
,
eed
.
25
E
Selection
of soft start
El
operation
E2
Soft
start
Selection
ofPI or
P
control
by
©
PI
control
26
F
ACR
control
method
"A
P
contr
ol
Selection
ofPI or
P
control
by
©
Pc
mntrol
Plug
27
H
ASR
control
method
©
P1
control
control
Selection
Selection
of
zero-speed
condi-
J 1
block
after
motor
28
tion at
motor
overheat
.
reached
zero
speed
by
J
stop
o
.eration
.
~~
ime(giate
gate
block
.
29
K
Selection
of
start
interlock
©Wit
zero-speed
condition
.
~~
Without
Selection
of
zero-speed
cord-
Field
half-reduced
after
tion at
motor
blower
stop
.
ttiotor
zero-speed
by
stop
30
L
_operation
.
(Gate
block)
Field
half-reduced
immediately
.
-
(Gate
block)
Selection
of
exciter
according
I©Exciter
used
.
31
M
to
typeof
motor
field
.
©
Exciter
not
used
.
Open
"
Speed
control
by
voltage
detection
.
"
Speed
control
by
AC
Short-
32
OPN
tach-gen
.
circuit
Short
-
Jumper
circuited
other
than the
above
.
Open
-
Special
application
.
33
OPS
--
Short-
Other
than
the
above
.
circuited

Related product manuals