Peripheral address:
n This parameter is available in CPUs from VIPA or in S7-300 CPUs from Siemens.
n Configured base address of the input area of the System SLIO frequency measure-
ment module, which is to be read from. The address is hexadecimal.
n (Example: Address 100: LADDR_IN: = W#16#64)
HW identifier:
n This parameter is only available in S7-1500 CPUs of Siemens.
n Enter at HW_ID the HW identifier, with which your module can be addressed accord-
ingly.
Ä
Chap. 4.1 ‘HW identifier - HW_ID’ page 66
Enter here the resolution in increments per revolution for the corresponding channel .
Ready signal of the function
n TRUE: Function was finished without error.
n FALSE: Function is not active respectively there is an error.
Currently determined rotational speed of the corresponding channel in revolutions per
minute (rpm).
LADDR_IN
HW_ID
RESOLUTION_CHx
DONE
SPEED_CHx
VIPA SPEED7
Device Specific
Frequency Measurement > FC 303 - FM_GET_SPEED - Calculate rotational speed consistent
HB00 | OPL_SP7 | Operation list | en | 18-30 254