13.2.1.4.2 Hardware configuration
To be compatible with the Siemens SIMATIC Manager the following steps should be exe-
cuted:
1. Start the Siemens hardware configurator with a new project.
2. Insert a profile rail from the hardware catalog.
3. Place at ‘Slot’ number 2 the CPU 315-2 PN/DP (315-2EH14 V3.2).
4. The integrated PROFIBUS DP master (jack X3) is to be configured and connected
via the sub module ‘X1 MPI/DP’ .
5. The integrated EtherCAT master is to be configured via the sub module ‘X2 PN-IO’
as a virtual PROFINET network.
6. Click at the sub module ‘PN-IO’ of the CPU.
7.
Select ‘Context menu è Insert PROFINET IO System’.
8. Create with [New] a new sub net and assign valid address data
9. Click at the sub module ‘PN-IO’ of the CPU and open with ‘Context menu
è Properties’ the properties dialog.
10. Enter at ‘General’ a ‘Device name’ . The device name must be unique at the
Ethernet subnet.
Configuring the CPU in
the project
VIPA SPEED7
Motion control - Simple Motion Control Library
Usage Sigma-5/7 EtherCAT > Usage Sigma-5 EtherCAT
HB00 | OPL_SP7 | Operation list | en | 18-30 305