For simplicity, the connection of the FB 860 - VMC_AxisControl is to be shown here. This
universal block supports simple motion commands and returns status messages. The
inputs and outputs can be individually connected. Please specify the reference to the cor-
responding axis data at ‘Axis’ in the axis DB.
FB 860 - VMC_AxisControl, DB 860
Ä
Chap. 13.7.2.2 ‘FB 860 - VMC_AxisControl -
Control block axis control’ page 544
ð
CALL "VMC_AxisControl" , "DI_AxisControl01"
AxisEnable :="AxCtrl1_AxisEnable"
AxisReset :="AxCtrl1_AxisReset"
HomeExecute* :="AxCtrl1_HomeExecute"
HomePosition* :="AxCtrl1_HomePosition"
StopExecute :="AxCtrl1_StopExecute"
MvVelocityExecute :="AxCtrl1_MvVelExecute"
MvRelativeExecute* :="AxCtrl1_MvRelExecute"
MvAbsoluteExecute* :="AxCtrl1_MvAbsExecute"
PositionDistance* :="AxCtrl1_PositionDistance"
Velocity :="AxCtrl1_Velocity"
Acceleration :="AxCtrl1_Acceleration"
Deceleration :="AxCtrl1_Deceleration"
JogPositive :="AxCtrl1_JogPositive"
JogNegative :="AxCtrl1_JogNegative"
JogVelocity :="AxCtrl1_JogVelocity"
JogAcceleration :="AxCtrl1_JogAcceleration"
JogDeceleration :="AxCtrl1_JogDeceleration"
AxisReady :="AxCtrl1_AxisReady"
AxisEnabled :="AxCtrl1_AxisEnabled"
AxisError :="AxCtrl1_AxisError"
AxisErrorID :="AxCtrl1_AxisErrorID"
DriveWarning :="AxCtrl1_DriveWarning"
DriveError :="AxCtrl1_DriveError"
DriveErrorID :="AxCtrl1_DriveErrorID"
IsHomed* :="AxCtrl1_IsHomed"
ModeOfOperation :="AxCtrl1_ModeOfOperation"
PLCopenState :="AxCtrl1_PLCopenState"
ActualPosition* :="AxCtrl1_ActualPosition"
ActualVelocity :="AxCtrl1_ActualVelocity"
CmdDone :="AxCtrl1_CmdDone"
CmdBusy :="AxCtrl1_CmdBusy"
CmdAborted :="AxCtrl1_CmdAborted"
CmdError :="AxCtrl1_CmdError"
CmdErrorID :="AxCtrl1_CmdErrorID"
DirectionPositive :="AxCtrl1_DirectionPos"
DirectionNegative :="AxCtrl1_DirectionNeg"
SWLimitMinActive* :="AxCtrl1_SWLimitMinActive"
SWLimitMaxActive* :="AxCtrl1_SWLimitMaxActive"
HWLimitMinActive* :="AxCtrl1_HWLimitMinActive"
HWLimitMaxActive* :="AxCtrl1_HWLimitMaxActive"
Axis :="Axis01".Axis
*) This Parameter is not supported by an inverter.
For complex motion tasks, you can use the PLCopen blocks.
Please specify the reference to the corresponding axis data at
Axis in the axis DB.
Your project now includes the following blocks:
n OB 1 - Main
n OB 57 - DP Manufacturer Alarm
n OB 82 - I/O_FLT1
Connecting the block for
motion sequences
VIPA SPEED7
Motion control - Simple Motion Control Library
Usage inverter drive via EtherCAT > Usage in VIPA SPEED7 Studio
HB00 | OPL_SP7 | Operation list | en | 18-30 525