4.1 Addition of I/O Modules
4-2
*3
The current status of the mounted I/O module is displayed.
*4
Confirm that each station (ST#) is the correct status.
*5
The status of the mounted I/O module for the rest of the stations appears. Confirm
them.
If the slot display is different, check the status again. If the status is correct, the I/O module
may be defective. Contact your Yaskawa representative.
IO MODULE
ST#01 DI-008 DO-008 AI-002 AO-002
ST#02 DI-016 DO-016
ST#03 NONE
ST#04 NONE
ST#05 NONE
ST#06 NONE
ST#07 NONE
ST#08 NONE
!Maintenance Mode
DI - 016
Number
Type
DI: Digital Input
DO: Digital Output
AI: Analog Input
AO: Analog Output
NOTE
IO MODULE
ST#08 NONE
ST#09 NONE
ST#10 NONE
ST#11 NONE
ST#12 NONE
ST#13 NONE
ST#14 NONE
ST#15 DI-040 DO-040
!Maintenance Mode