EasyManua.ls Logo

YASKAWA YASNAC XRC - Page 432

YASKAWA YASNAC XRC
561 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.3 Alarm Message List
10-42
4434 VAR-SCOREBOARD
CONTROL ERROR
[Decimal Data]
The error occurred in variable scoreboard
control.
• Reset the alarm. Select job and repeat
the operation.
• If the error occurs again, operate by the
following procedure:
#
Delete the command that caused the
alarm and register again and start exe-
cution.
&
Delete the job that cause the alarm and
register again and start execution.
• If the error occurs again, contact your
YASKAWA representative.
4435 UNDEFINED LOCAL-
VARIABLE
[Bit Pattern]
The local variable was undefined. Set the local variable used for sub header
of job.
4436 LESS THAN 3
STEPS(CIRCULAR)
[Decimal Data]
A circle step didn't contain a minimum of 3
consecutive points.
Reset the alarm. Teach at least 3 consec
utive points for the circle step.
4437 LESS THAN 3
STEPS(SPLINE)
A spline interpolation designation step didn't
contain a minimum of 3 consecutive points.
Reset the alarm. Teach at least 3 consec
utive points for the spline interpolation
designation step.
4438 UNDEFINED JOB
[Decimal Data]
Job was not registered. Reset the alarm and register job. Or
Delete CALL, JUMP instruction caused
the alarm.
4439 UNDEFINED LABEL
[Decimal Data]
No labels existed in the currently executing
job.
Reset the alarm and register job. Or
Delete CALL, JUMP instruction occurred
the alarm.
4440 UNDEFINED
RETURN JOB
[Decimal Data]
The job call stack contained no return. Reset the alarm and start execution from
the master job. Or delete RET instruction.
4441 LACK OF LOCAL-
VARIABLE AREA
[Decimal Data]
Too many local variables used in the job. Reset the alarm and reduce the use num-
ber of the local variables
4442 LOCAL-VARIABLE
CONTROL ERROR
[Decimal Data]
When job was executed, the error occurred
in control process of local variable.
Data (1-4) stands for the alarm factor.
• Reset the alarm. Select job and repeat
the operation.
• If the error occurs again, operate by fol-
lowing procedure:
#
Delete the command that caused the
alarm and register again and start exe-
cution.
&
Delete the job that caused the alarm
and register again and start execution.
4443 JOB CALL STACK
ERROR
[Decimal Data]
At the job CALL, RET, END instruction,
when operating the job call stack, internal
control data of inside was abnormal.
Data (1-2) stands for the alarm factor.
• Reset the alarm. Select the job again
and repeat the operation.
• If the error occurs again, contact your
YASKAWA representative.
Alarm Message List
Alarm
Number
Message Cause Remedy

Table of Contents