10 Cable Wiring
10.1 Disconnecting Cables
10-6
159281-1CD
HW1480357
HP20D
10.1.3 Cables in S-Head
• Refer to Table 10-3 "S-Head Cable Wiring Parts Checklist" and Fig.
10-3 “S-Head Cable Wiring”.
1. Remove the cross head APS bolts , then remove the cover . Then,
cut off the cable tie which fixes the internal wiring harness.
2. Connect the backup batteries to the S-axis motor and the L-axis motor.
3. Disconnect the connectors (signal, power, brake) connected to the
S-axis motor and the L-axis motor.
4. Remove the cross head APS bolts , then remove the tube for grease
exhaust on the back of the cover. Then, remove the cover .
5. Disconnect the connector of the S-axis motor from the internal wiring
harness.
6. Remove the GT-SA bolts . Then, pull out the holder which fixes
the internal wiring harness.
7. Remove the hexagon socket head cap screws , then remove the
saddle .
8. Cut off the cable tie which fixes the internal wiring harness, then
remove the holder .
9. Remove the GT-SA bolts , then remove the cover .
10. Remove the GT-SA bolts , then remove the holder .
11. Pull out the internal wiring harness from the S-head, then remove the
GT-SA bolts . Then, remove the saddle , cut off the cable tie, and
remove the holder .
12. Remove the cross head APS bolts , then pull out the C-base .
13. Remove the tube for grease replenishment installed on the back of the
C-base .
14. Pull out the C-base further, and remove the internal wiring harness.
2
1
4
3
2
6
7
8
6
11
12
13
14
15
16
14
9
10
10
10