4.2 Addition of Base and Station Axis
4-3
*6
The confirmation dialog is shown.
*7
The system parameters are then set automatically according to the current mounted
hardware status. The procedure for the addition of the I/O module is complete.
4.2
Addition of Base and Station Axis
For addition of base and station axis, mount all hardware correctly and then execute mainte-
nance mode.
*1
The system display is shown.
The additional operation must be done in the management mode.
In operation mode or editing mode, only confirmation of status setting is possible.
Turn the power supply ON while pressing [TOP MENU] simultaneously Select {SYS-
TEM} under the top menu
*1
Select {SETUP}
*2
Select {CONTROL GROUP}
*3
(Display moves to the control group display.)
IO MODULE
ST#08 NONE
ST#09 NONE
ST#10 NONE
ST#11 NONE
ST#12 NONE
ST#13 NONE
ST#14 NONE
ST#15 DI-040 DO-040
!Maintenance Mode