7.5 General I/O Signal Assignment
7-40
*1
A master job is a job (program) which can be called by CALL MASTER JOB.
Other functions are the same as for normal jobs. Normally, the parent job, which man-
ages the child jobs called up immediately after the power is turned ON, is set as the
master job.
*2
See " 3.7 Interference Area ".
Specific Input List XIU01 (General application)
Logical
Number
Input Name / Function
Logical
Number
Input Name / Function
2010 EXTERNAL START
Functions the same as the [START] button in
the playback panel. Only the rising edge of the
signal is valid. It starts robot operation (play-
back). This signal is invalid if external start is
prohibited from the playback condition display.
2020 INTERFERENCE 1 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cub
1
*2
area while this signal is ON, the manipula-
tor goes to wait status (with servo power ON).
During wait status, the manipulator operation
restarts if this signal turns OFF.
2012 CALL MASTER JOB
Only the rising edge of the signal is valid. It
calls up the top of the robot program, that is the
top of the master job
*1
. This signal is invalid
during playback, during teach-lock and when
play master or call is prohibited (set from the
playback operation condition display).
2021 INTERFERENCE 2 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cub
2
*2
area while this signal is ON, the manipula-
tor goes to wait status (with servo power ON).
During wait status, the manipulator operation
restarts if this signal turns OFF.
2013 ALARM/ERROR RESET
After an alarm or error has occurred and the
cause been corrected, this signal resets the
alarm or error.
2022 WORK PROHIBITED (Tool ON Prohibited)
Even if TOOLON instruction is executed, XRC
doesn’t output to external while this signal is
ON.
2014 SELECT REMOTE MODE
Functions the same as [REMOTE] on the play-
back panel. Valid only while the signal is ON. It
selects the REMOTE mode.
2024 INTERFERENCE 3 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cub
3
*2
area while this signal is ON, the manipula-
tor goes to wait status (with servo power ON).
During wait status, the manipulator operation
restarts if this signal turns OFF.
2015 SELECT PLAY MODE
Functions the same as [MODE] on the play-
back panel. Only the rising edge of the signal is
valid. It selects the PLAY mode. If designated
simultaneously with other modes, the TEACH
mode takes priority. This signal is invalid if
external mode selection is prohibited from the
operation condition display.
2025 INTERFERENCE 4 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cub
4
*2
area while this signal is ON, the manipula-
tor goes to wait status (with servo power ON).
During wait status, the manipulator operation
restarts if this signal turns OFF.
2016 SELECT TEACH MODE
The TEACH mode is selected if this signal
turns ON during PLAY mode. Switching to
other modes is disabled while this signal is ON.
If this signal turns ON while the SELECT PLAY
MODE signal is ON, this signal takes priority
and the TEACH mode is selected.

Table of Contents