AL-0930 to 0932,0960 to 0965 (CPU HANG UP ERROR)
An NMI error (origin unknown) occurs.
AL-0999 (NMI ERROR)
Continue normal operation.
Continue normal operation.
The defective board caused the alarm.
Contact your Yaskawa
representative.
No
Yes
Yes No
NoYes
Alarm?
Alarm?
Alarm?
Check the connection of
the corresponding board.
(See the table below.)
Replace the board. Continue normal operation.
An alarm occurs.
Turn the power OFF and then ON.
An error occurs during the internal control check.
AL0930
AL096
0
AL0963
AL093
1
AL096
1
AL093
2
AL096
2
AL0964
AL0965
Continue normal operation.
No
Yes
Yes No
Alarm?
Alarm?
Check the connections of all the boards.
Contact your Yaskawa representative. Continue normal operation.
An alarm occurs.
Turn the power OFF and then ON.
XCP01 circuit board
XCP02 #1
circuit board
WRCA01 #1
circuit board
XCP02 #2
circuit board
WRCA01 #2
circuit board
WRCA01 #3
circuit board
WRCA01 #4
circuit board
WRCA01 #5
circuit board
WRCA01 #6
circuit board
22