4. BASIC OPERATION
c) 2ndpageofsettingscreen:Screenforthemainsweepsettings
The figure is an example that shows frequency selection as the sweep type.
Sweep start value
Sweep stop value
Sweep time
Sweep mode
Sweep function
Sweep type
Sweep marker value
Two soft key stages
Single-shot, gated single-
shot sweep trigger
Indicates that the
2nd page is
displayed.
Press the NEXT
key to switch to
the 3rd page.
Sweep type [Type]
This is the type of sweep. Frequency, phase, amplitude, DC offset, and duty can be chosen from.
p.90
Sweep start value [Start]
This is the sweep start value.
Sweep stop value [Stop]
This is the sweep stop value.
Sweep time [Time]
This is the transition time from the start value to the stop value.
Sweep mode [SwpMode]
This is the sweep oscillation mode. Continuous sweep, single-shot sweep, and gated single-shot
sweep can be chosen from. p.91
Trigger [Trig]
This is the trigger condition for single-shot sweep and gated single-shot sweep.
Internal and external can be chosen as the trigger source. p.94
Sweep function [SwpFctn]
This is the sweep form. One-way and shuttle can be chosen from. Linear and log are also possible
if the sweep type is frequency. p.90
Sweep marker value [Marker]
This is the sweep marker value. p.96